Good laboratory practice
The Principles of Good Laboratory Practice (GLP) establish rules and criteria for a quality system that oversees the organizational processes and conditions in which non-clinical health and environmental safety studies are planned, conducted, monitored, recorded, reported, and archived.[1][2] These principles apply to the non-clinical safety testing of substances found in various products to ensure the quality and integrity of the safety data submitted to regulatory authorities globally.[3][4]
History
The historical events leading to the proposal of the Good Laboratory Practice (GLP) regulations are crucial for understanding why these regulations are important for assuring the quality and integrity of nonclinical safety data.[5] These regulations were developed in response to concerns about the reliability and consistency of safety data used in assessing the potential risks of chemicals and products to humans and the environment. The GLP regulations aim to standardize procedures and practices in nonclinical studies to ensure accurate, reliable, and traceable data. This background helps highlight the significance of adhering to GLP standards in research and regulatory contexts.
GLP was first introduced in New Zealand and Denmark in 1972.[6]
During the 1960s and 1970s in the United States, a growing concern for environmental issues and health impacts of chemicals prompted increased federal regulation, particularly in the chemical and pharmaceutical sectors, leading to more stringent product testing requirements and the development of inspection programs targeting laboratories conducting animal research. These initiatives, initiated by the Office of New Drugs and the Office of Marketed Drugs in 1969 and later expanded with the Office of Compliance, included inspections of facilities with questionable study validity or misconduct tips, revealing significant quality control issues and deficiencies in animal toxicological testing standards and data reporting.[5]
Industrial BioTest Labs (IBT) was the most notable case where thousands of safety tests for chemical manufacturers were either falsely claimed to have been performed or were of such poor quality that police investigators could not determine the extent of the work completed, despite superficially delivering test results as specified in their contracts with the manufacturers.[7] IBT, a contract laboratory based in Northbrook, Illinois, conducted research for the United States government and various chemical and pharmaceutical companies, both from the U.S. and abroad, and submitted toxicology data to several federal agencies, covering a wide range of products including drugs, insecticides, herbicides, food additives, pesticides, cosmetics, and cleaning products.[5]
These issues were made public in the hearings at the US Congress, which led to the FDA's publication of Proposed Regulations on GLP on November 19, 1976,[8] and establishment of the Final Rule in June 1979[9] which became effective on June 20, 1979.[10] Proposed amendments were introduced on October 29, 1984.[11] The GLP amendment Final Rule was published on September 4, 1987[12] and became effective on October 5, 1987.[5]
The Environmental Protection Agency (EPA) had also encountered similar problems in data submitted to it, and issued its own draft GLP regulations in 1979 and 1980, publishing the Final Rules in two separate parts (40 CFR 160 and 40 CFR 792) in 1983.[13][14][15]
U.S. Food and Drug Administration (21 CFR Part 58)
The FDA requires nonclinical laboratory studies on new drugs, food additives, and chemicals to assess their safety and potential effectiveness in humans in compliance with 21 CFR Part 58, Good Laboratory Practice for Nonclinical Studies under the Federal Food Drug and Cosmetic Act and Public Health Service Act.[16] These regulations set the standards for conducting nonclinical laboratory studies that support or are intended to support applications for research or marketing permits for products such as food additives, drugs, medical devices, or biological products.[17] Conducting these studies with rigorous adherence to scientific principles and quality control is crucial, as the decisions based on their outcomes directly affect human health and safety.[5] By adhering to the requirements outlined in 21 CFR Part 58, laboratories conducting nonclinical studies can ensure that the data generated are of high quality, reliable, and suitable for submission to the Agency as part of product approval processes.
Compliance with GLP regulations helps to protect the safety and welfare of humans and animals involved in studies and contributes to the overall integrity of scientific research in the development of FDA-regulated products.[5] GLP compliance inspections are assessed and performed under the Agency's Bioresearch Monitoring (BIMO) program and carried out by trained BIMO inspectors.[5][17][18][19] Serious noncompliance is dealt with by procedures ranging from study rejection to laboratory disqualification.[17]
Since June 20, 1979, the FDA has received many questions about Good Laboratory Practice (GLP) regulations (21 CFR 58). The responses to these inquiries are stored in the Dockets Management Branch (HFA-305) and shared with the Agency's Bioresearch Monitoring (BIMO) program managers and district offices to ensure consistency. Consequently, the US FDA published the 1981 Questions & Answers - Good Laboratory Practice Regulations document to consolidate and clarify these responses. This Q&A document categorizes responses by specific GLP provisions to make them more useful for both the FDA headquarters and field offices.[20]
The FDA has signed a memorandum of understanding (MOU) with Canada,[21] France,[22] Germany,[23] Italy,[24] Japan,[25] The Netherlands,[26] Sweden,[27] and Switzerland[28] to enhance cooperation on good laboratory practice (GLP) for nonclinical laboratory studies supporting product approvals, aiming to facilitate information exchange and inspections for regulatory oversight.[29]
Proposed amendments were published in the Federal Register on August 24, 2016, which aimed to require a comprehensive quality system approach known as a GLP Quality System to enhance the current quality system approach for nonclinical laboratory studies.[30][31] This system would be mandatory for safety and toxicity studies that support or are intended to support applications or submissions for products regulated by the FDA.[32] Proposed modifications to the GLP Quality System include additional responsibilities for testing facility management and SOP maintenance, along with expanded definitions applicable to all nonclinical laboratory studies, aiming to enhance roles and functions aligned with the revised testing facility definition and to establish a framework for improving data reliability in regulatory decision-making.[30][31]
The EPA's Good Laboratory Practice Standards (GLPS) compliance monitoring program guarantees the accuracy and reliability of test data submitted to the Agency to support pesticide product registration under the Federal Insecticide, Fungicide and Rodenticide Act (FIFRA), section 5 of the Toxic Substances Control Act (TSCA), and in accordance with testing consent agreements and rules issued under section 4 of TSCA. The Agency utilizes data obtained from laboratory inspections and audits to oversee the use of pesticides and industrial chemicals.[33]
40 CFR Part 160, Good Laboratory Practice Standards pertains specifically to the Good Laboratory Practice (GLP) standards for pesticide chemicals. It establishes the requirements for conducting studies and generating data used for the registration of pesticides under the Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA). This regulation applies primarily to studies conducted to support the registration or re-registration of pesticide products under FIFRA. It includes studies related to human health and environmental effects of pesticides. It focuses specifically on studies related to pesticide products, including toxicity studies, residue chemistry studies, environmental fate studies, and other types of studies required for pesticide registration. It operates within the context of pesticide regulation under FIFRA, which is specific to the registration and use of pesticides in the United States.[14]
40 CFR Part 792, Good Laboratory Practice Standards, covers the broader application of GLP standards for nonclinical laboratory studies conducted for assessing the safety or efficacy of chemical substances, including pesticides, under various regulatory programs overseen by the EPA. This regulation applies to nonclinical laboratory studies conducted for various purposes beyond pesticides, encompassing studies related to chemicals, drugs, food additives, and other substances regulated by the EPA. This part has a broader scope and is applicable to a wider range of substances and regulatory programs. It covers a more diverse range of nonclinical studies, including those related to chemical substances other than pesticides. This could include studies conducted for assessing the safety of industrial chemicals, pharmaceuticals, food additives, and other substances subject to EPA regulation. It operates across various regulatory programs within the EPA, reflecting a broader framework for ensuring the quality and reliability of nonclinical study data used in regulatory decision-making.[15]
While both 40 CFR Part 160 and 40 CFR Part 792 address GLP standards for laboratory studies, they differ significantly in terms of scope, applicability, and the specific regulatory context in which they operate. Part 160 is tailored to pesticide registration under FIFRA, whereas Part 792 is a more comprehensive framework applicable to a wider range of nonclinical studies conducted for regulatory purposes across different EPA programs.[33]
The OECD Principles of Good Laboratory Practice (GLP) cover the testing of chemicals or chemical products in non-clinical settings, either in laboratory conditions or environmental settings, such as greenhouses and field experiments. These principles exclude studies involving human subjects. Depending on the location or governing rules in an OECD-member country, the OECD Principles of GLP might also extend to non-clinical safety testing of other regulated items, like medical devices.[3]
Examples studies conducted under GLP in OECD-member countries include:
- Physical-chemical testing;
- Toxicity studies;
- Mutagenicity studies;
- Environmental toxicity studies on aquatic and terrestrial organisms;
- Studies on behavior in water, soil, and air; bioaccumulation;
- Studies to determine pesticide residues in food or animal feedstuffs;
- Studies on effects on mesocosms and natural ecosystems;
- Analytical and clinical chemistry testing.
Safety testing data must be submitted to regulatory authorities for product marketing authorization. During the review process, the submitted data undergoes verification to ensure compliance with Good Laboratory Practice (GLP) standards. Additionally, the GLP compliance status of the testing facility where the study was conducted is assessed by referring to inspection information from national GLP compliance monitoring programs.
OECD member countries where non-clinical health and environmental safety testing follows the OECD Principles of Good Laboratory Practice (GLP) have established national GLP Compliance Monitoring Programs (CMP) responsible for overseeing GLP compliance of test facilities within their jurisdictions. These CMPs verify GLP compliance through inspections of test facilities and audits of GLP studies. Test facilities that undergo periodic inspections by a CMP and are found to operate in accordance with GLP principles are recognized as GLP compliant.
In OECD-member countries, testing facilities seeking recognition as GLP compliant can apply to the national CMP. The CMP then conducts inspections to assess if the test facility adheres to the OECD Principles of GLP. In other countries, CMPs have the authority to inspect any test facility that claims to conduct studies according to GLP standards.
The chemicals industry, which includes industrial chemicals, pharmaceuticals, pesticides, biocides, food and feed additives, and cosmetics, ranks as one of the largest industrial sectors in the world.[34] Harmonizing national approaches to chemical regulation offers several benefits: it streamlines requirements for industry, provides governments with a common framework for collaboration, and reduces trade barriers.[3] The OECD Mutual Acceptance of Data (MAD) system, comprising a series of OECD Council Decisions along with OECD Guidelines for Testing Chemicals and OECD Principles of Good Laboratory Practice (GLP), is instrumental in achieving this harmonization.
The MAD system aims to avoid conflicting or redundant national regulations, foster cooperation among national authorities, and eliminate trade barriers. Under this system, OECD countries and full adherents agree that safety tests conducted according to OECD Test Guidelines and Good Laboratory Practice in one country should be accepted by others for assessment purposes—a principle known as "tested once, accepted for assessment everywhere." This approach saves the chemicals industry from the expense of duplicative testing for products marketed in multiple countries. Although the receiving government must accept the study, it retains the discretion to interpret the study results according to its own criteria.[3][34]
According to OECD Council Decision C(97)186/Final, chemical testing data generated in any OECD member country following OECD Test Guidelines and GLP principles is recognized by other OECD member countries, such as Australia, Canada, Korea, and the USA. This recognition also extends to some non-OECD countries that fully adhere to the mutual acceptance of data (MAD) under OECD Council Decision C(97)114/Final, including Brazil, India, Malaysia, Singapore, and South Africa, as well as Argentina for industrial chemicals, pesticides, and biocides only.[35]
In June 2004, the US FDA published a comparison chart of FDA and EPA Good Laboratory Practice (GLP) regulations alongside OECD Principles for GLP, aiding in understanding the key differences and similarities in GLP standards across these regulatory bodies.[36]
European Union[35]
The Principles of Good Laboratory Practice (GLP) ensure the quality and accuracy of data in chemical testing and help prevent fraud. These principles are developed by the Organisation for Economic Cooperation and Development (OECD) and adopted by the European Union (EU).[4][37][38] European GLP Regulations and Directives also apply to European Economic Area (EEA) member states which include Iceland, Liechtenstein, and Norway. GLP principles govern the non-clinical safety testing of substances in various products, mandated by product-specific legislation in the EU/EEA.[4][35][39]
Directive 2004/9/EC mandates EU/EEA countries to designate GLP inspection authorities and includes requirements for reporting and mutual acceptance of data within the internal market. Annex I of the Directive incorporates OECD Revised Guides for Compliance Monitoring Procedures for GLP, along with OECD Guidance for the Conduct of Test Facility Inspections and Study Audits. It ensures compliance with these guidelines during laboratory inspections and study audits. This directive replaced Directive 88/320/EEC as of 11 March 2004.[4][35][37]
Directive 2004/10/EC, the second core EU GLP Directive, harmonizes laws and administrative provisions for applying GLP principles and verifying their implementation in chemical substance tests. It includes GLP principles in Annex I and requires EU/EEA countries to ensure that laboratories conducting safety studies on chemical products comply with OECD GLP principles. It replaces Directive 87/18/EEC.[4][35][38]
The Clinical Trials Facilitation Group (CTFG) of the Heads of Medicines Agency issued a Q&A document in 2017 addressing Good Laboratory Practice (GLP) requirements within the context of clinical trials for human medicines. This document aims to provide clarification and guidance on GLP principles applicable to non-clinical safety studies conducted as part of clinical trial applications.[40]
In March 2024, the Clinical Trials Coordination Group (CTCG) of the Heads of Medicines Agencies released a new recommendation paper on the principles of Good Laboratory Practices (GLP) for clinical trial applications governed by the EU Clinical Trials Regulation (Regulation (EU) No 536/2014).[41] This paper was developed in collaboration with relevant groups from the European Medicines Agency (EMA) and the European Commission (EC) to clarify the applicable regulatory requirements and ensure transparency regarding the level of information required about GLP status in Clinical Trial Applications.[41][42] This will assist researchers and sponsors in understanding what is expected and how to include the necessary information to support their applications.[42]
GLP supports the sharing of test data between countries, which helps avoid repeated testing, benefits animal welfare, and saves money for businesses and governments. Having common GLP standards also makes it easier to share information and prevents trade barriers, while helping to protect human health and the environment. The EU has established Mutual Recognition Agreements for GLP with Israel, Japan, and Switzerland.[35]
Notes and references
- ^ "OECD Principles of Good Laboratory Practice (as revised in 1997)". OECD Environmental Health and Safety Publications. 1. OECD. 1998. Archived from the original on 20 April 2010. Retrieved 15 October 2006.
- ^ "Good laboratory practice compliance | European Medicines Agency". www.ema.europa.eu. Retrieved 2024-06-18.
- ^ a b c d e "OECD Principles of Good Laboratory Practice (GLP) and GLP Compliance Monitoring". Organisation for Economic Co-operation and Development. Retrieved April 28, 2024.
- ^ a b c d e "EU Legislation with Good Laboratory Practice (GLP) Provisions". EU Environmental Legislation: 89–90. March 2024. doi:10.4337/9781781954775.00012. Retrieved June 18, 2024.
- ^ a b c d e f g Baldeshwiler, Anne (29 July 2003). "History of FDA good laboratory practices". The Quality Assurance Journal. 7 (3): 157–161. doi:10.1002/qaj.228. eISSN 1099-1786. ISSN 1087-8378 – via Wiley Online Library.
- ^ Kevin Robinson for BioPharm International, 1 Aug 2003. GLPs and the Importance of Standard Operating Procedures Archived 21 March 2005 at the Wayback Machine
- ^ Schneider, K (Spring 1983). "Faking it: The case against Industrial Bio-Test Laboratories". Amicus Journal. Natural Resources Defence Council: 14–26. Archived from the original on 14 February 2012. Retrieved 16 April 2011.
- ^ "Good Laboratory Practice (GLP), Proposed Rule, 11/19/1976". U.S. Food and Drug Administration. December 22, 2020 [November 19, 1976]. Retrieved April 23, 2024.
- ^ "Good Laboratory Practice (GLP) Final Rule, 12/22/1978". U.S. Food and Drug Administration. December 22, 2020 [December 22, 1978]. Retrieved April 23, 2024.
- ^ "Good Laboratory Practice Regulations Management Briefings Post Conference Report". U.S. Food and Drug Administration. February 24, 2020 [August 1979]. Retrieved April 23, 2024.
- ^ "Good Laboratory Practice (GLP), Proposed Rule, 10/29/1984". U.S. Food and Drug Administration. December 22, 2020 [October 29, 1984]. Retrieved April 23, 2024.
- ^ "Good Laboratory Practice (GLP), Amendment, Final Rule, 9/4/1987". U.S. Food and Drug Administration. December 22, 2020 [September 4, 1987]. Retrieved April 23, 2024.
- ^ Staff, World Health Organization (2009) Handbook: Good Laboratory Practice (GLP) Archived 9 February 2021 at the Wayback Machine
- ^ a b "GOOD LABORATORY PRACTICE STANDARDS". www.govinfo.gov. Retrieved 2024-04-17.
- ^ a b "GOOD LABORATORY PRACTICE STANDARDS". www.govinfo.gov. Retrieved 2024-04-17.
- ^ "CFR - Code of Federal Regulations Title 21". www.accessdata.fda.gov. Retrieved 2024-04-12.
- ^ a b c "MOU Among USDA/FDA/NIH | OLAW". olaw.nih.gov. Retrieved 2024-04-23.
- ^ "Bioresearch Monitoring Program (BIMO) Compliance Program 7348.808 Good Laboratory Practice (Nonclinical Laboratories)". U.S. Food and Drug Administration. May 1, 2018. Retrieved April 23, 2024.
- ^ "Bioresearch Monitoring Program (BIMO) Compliance Program 7348.810 Sponsors and Contract Research Organizations". U.S. Food and Drug Administration. September 15, 2021. Retrieved April 23, 2024.
- ^ "1981 Questions & Answers - Good Laboratory Practice Regulations". U.S. Food and Drug Administration (published July 2007). 1981 [June 1981]. Retrieved 12 April 2024.
- ^ "FDA - Health and Welfare Canada HPB, MOU on GLPs and Inspection Programs". U.S. Food and Drug Administration. 30 January 2018. Retrieved 18 April 2024.
- ^ "FDA - France, MOU Regarding Collaboration and Cooperation". U.S. Food and Drug Administration. 30 January 2018. Retrieved 18 April 2024.
- ^ "FDA - Germany, MOU on Good Laboratory Practice". U.S. Food and Drug Administration. 31 January 2018. Retrieved 18 April 2024.
- ^ "FDA - Italy, MOU Regarding Safety Evaluation Data". U.S. Food and Drug Administration. 31 January 2018. Retrieved 18 April 2024.
- ^ "FDA - Japan, GLP Mutual Recognition - Japanese Note Verbal". U.S. Food and Drug Administration. 31 January 2018. Retrieved 18 April 2024.
- ^ "FDA - Netherlands, MOU Regarding Good Laboratory Practice". U.S. Food and Drug Administration. 31 January 2018. Retrieved 18 April 2024.
- ^ "FDA - Sweden, MOU Regarding Good Laboratory Practice (GLP)". U.S. Food and Drug Administration. 31 January 2018. Retrieved 18 April 2024.
- ^ "FDA - Switzerland, MOU Regarding Good Laboratory Practice (GLP)". U.S. Food and Drug Administration. 31 January 2018. Retrieved 18 April 2024.
- ^ "Cooperative Arrangements". U.S. Food and Drug Administration. 23 February 2024. Retrieved 18 April 2024.
- ^ a b "Good Laboratory Practice for Nonclinical Laboratory Studies". U.S. Food and Drug Administration. March 26, 2018. Retrieved April 17, 2024.
- ^ a b "Good Laboratory Practice for Nonclinical Laboratory Studies - A Proposed Rule by the Food and Drug Administration on 08/24/2016". Federal Register - The Daily Journal of the United States Government. 24 August 2016. Retrieved 17 April 2024.
- ^ "Regulations.gov". www.regulations.gov. Retrieved 2024-04-17.
- ^ a b c US EPA, OECA (2013-07-30). "Good Laboratory Practices Standards Compliance Monitoring Program". www.epa.gov. Retrieved 2024-04-17.
- ^ a b c "Mutual Acceptance of Data (MAD)". Organisation for Economic Co-operation and Development. Retrieved April 28, 2024.
- ^ a b c d e f "Good Laboratory Practice - European Commission". single-market-economy.ec.europa.eu. Retrieved 2024-06-18.
- ^ "Comparison Chart of FDA and EPA Good Laboratory Practice (GLP) Regulations and the OECD Principles of GLP". U.S. Food and Drug Administration. April 7, 2015 [June 2004]. Retrieved April 23, 2024.
- ^ a b Directive 2004/10/EC of the European Parliament and of the Council of 11 February 2004 on the harmonisation of laws, regulations and administrative provisions relating to the application of the principles of good laboratory practice and the verification of their applications for tests on chemical substances (codified version) (Text with EEA relevance), 2009-04-20, retrieved 2024-06-18
- ^ a b Directive 2004/10/EC of the European Parliament and of the Council of 11 February 2004 on the harmonisation of laws, regulations and administrative provisions relating to the application of the principles of good laboratory practice and the verification of their applications for tests on chemical substances (codified version) (Text with EEA relevance), vol. 050, 2004-02-11, retrieved 2024-06-18
- ^ "Specific regulatory choices". EU Environmental Legislation: 89–90. doi:10.4337/9781781954775.00012.
- ^ "Question and Answer document on Good Laboratory Practice" (PDF). Heads of Medicines Agencies Clinical Trials Coordination Group. March 2017. Retrieved 18 April 2024.
- ^ a b "Recommendation paper on principles of Good Laboratory Practices (GLP) for clinical trial applications under the EU Clinical Trials Regulation (Regulation (EU) No 536/2014) Version 01" (PDF). Heads of Medicines Agencies Clinical Trials Coordination Group. March 2024. Retrieved 18 April 2024.
- ^ a b "Heads of Medicines Agencies: Clinical Trials Coordination Group". www.hma.eu. Retrieved 2024-04-18.
See also
- GxP
- Good clinical practice
- Good Automated Manufacturing Practice
- Joint Committee for Traceability in Laboratory Medicine
- International Federation of Clinical Chemistry and Laboratory Medicine (IFCC)
- Drug development
- ISO 15189
- Verification and Validation
Further reading
- Webster, Gregory K.; Kott, L; Maloney, T; et al. (2005). "JALA Tutorial: Considerations When Implementing Automated Methods into GxP Laboratories". Journal of the Association for Laboratory Automation. 10 (3). Elsevier: 182–191. doi:10.1016/j.jala.2005.03.003.
External links
- Comparison of difference versions of GLP (Comparison OECD, FDA and EPA GLP)
- Code of Federal Regulations Title 21 (Food and Drugs) Part 58 (Good Laboratory Practice for Nonclinical Laboratory Studies) (USA)
- Good Laboratory Practice (Organisation for Economic Co-operation and Development)
- OECD Series on Principles of Good Laboratory Practice and Compliance Monitoring
- Belgian Monitoring Authority for GLP
- TECHNOXMART Archived 2019-12-23 at the Wayback Machine
See what we do next...
OR
By submitting your email or phone number, you're giving mschf permission to send you email and/or recurring marketing texts. Data rates may apply. Text stop to cancel, help for help.
Success: You're subscribed now !